Built for density

One reference design, adapted to each site: live grid power with generator backup, redundant power to the rack, and air and liquid cooling in the same hall.

Reference design

Follow the power from the grid to the rack, then the heat back out. Select a stop to see it on the drawing. These are design targets; each site's datasheet states what is built.

GGGrid feed AGrid feed BGeneratorGeneratorUPSUPSBusway ABusway BAir-cooled rowLiquid-cooled rowAir unitsCDUDry coolersHeat reuse1234567
Power, side APower, side BStandby generatorHeatEESH reference hall, simplified

Projects

Capacity by status. The projects in development and the sites in the pipeline have live grid power.

ProjectStatusCapacityScopeReady for service
Earlier developmentsDelivered20 MW+Data-centre developments completed to dateCompleted
GPUs in productionOperatingNVIDIA H200AI workloads running on our own systems in BudapestRunning
AI projects I and IIIn developmentLive grid power1.6 MWData-centre build-out led by EESH, equipped with NVIDIA B300 systemsQ2 2027
Development pipelinePipelineLive grid power100 MW+Sites in the United States and Central EuropeBy project

Locations, single-line diagrams and dated datasheets for each project are part of the diligence pack.

How we build

Power first

We develop sites where grid power is already live. That holds for the projects in development and for every site in the pipeline.

Redundant to the rack

Two independent power paths reach every rack position, backed by UPS and standby generators. Maintenance on one side does not take the load down.

Hybrid from day one

Hardware generations change faster than buildings. Our halls carry air-cooled and liquid-cooled rows on the same plant, and a row can change from one to the other.

What a site datasheet covers

Each site has a dated datasheet with the fields operators, lenders and offtakers ask for. It is part of the diligence pack.

Power

  • Grid connection: capacity and status
  • IT load today and at full build
  • Power path and redundancy
  • Backup power and autonomy
  • Supply terms and price basis

Cooling and density

  • Sustained kW per rack
  • Air and liquid capacity
  • Design and measured PUE
  • Heat rejection and reuse

Space and network

  • Floor loading and rack positions
  • Delivery route and staging
  • Carriers and route diversity
  • Own IP space and BGP

Resilience and control

  • Maintenance concept
  • Incident history
  • Site control and term
  • Certification status

Ask for the diligence pack

Company documents, project summaries, site datasheets and draft contract terms, shared under NDA.